Shopping Basket

0 Items

Subtotal £0.00

Commercial kitchen suppression

Ceasefire Ultra Lite | Commercial Kitchen Fire Suppression System | LPCB LPS 1223

Ceasefire Ultra Lite | Commercial Kitchen Fire Suppression System | LPCB LPS 1223

Protect the kitchen. Protect the contract.

Commercial kitchens are one of the highest-risk fire environments in any building and your clients need a suppression system that's been built around that reality. The Ceasefire Ultra Series Wet Chemical Kitchen Fire Suppression System combines automatic detection, rapid knock-down, and powerful re-ignition prevention into a single LPCB certified package.

Whether you're specifying for a restaurant, hotel kitchen, or school canteen, this system gives you a compliant, reliable solution you can install with confidence.

Why installers specify the Ultra Series

  • LPCB certified under LPS 1223: A recognised benchmark for kitchen suppression systems, supporting compliance and sign-off.
  • Covers Class A, B, and F fires: Including cooking oil fires, the most common and dangerous kitchen fire type.
  • 24-hour automatic protection: Heat-sensing tube detection monitors the full length of the hood continuously, with no blind spots.
  • Wet chemical agent prevents re-ignition: The 90% water, 10% foam-based agent cools the cooking surface while forming a blanket that cuts off oxygen.
  • Biodegradable agent, minimal collateral damage: No flooding, no costly clean-up; residue can actually be used to clean cookware and surfaces.
  • Manual and automatic actuation: Dual-trigger flexibility ensures the system works whether the kitchen is staffed or not.
  • Stored-pressure design: Low maintenance compared to cartridge or pump-based alternatives, reducing call-backs and service costs.
  • Protects hood, duct, and plenum: Comprehensive coverage of the entire extraction zone, not just the cooking surface.
  • Flexible sizing: Available in 8, 12, 20, and 30 litre agent capacities to suit kitchens of different sizes and configurations.
  • In-house design support available: Bespoke layout design for every installation.

How it works

A specially designed pneumatic polymer heat-sensing tube runs the full length of the kitchen hood. When a fire is detected, the tube triggers the valve, discharging wet chemical agent through purpose-designed nozzles directly over the hazard zone. The agent simultaneously knocks down flames and cools the surrounding area to prevent re-ignition, all within seconds, automatically.

The system's intelligent mechanical control panel is fully assembled and tested prior to dispatch, giving you a straightforward, reliable installation every time.

Ceasefire kitchen suppression installation detail
Ceasefire kitchen suppression system detail

Technical overview

Agent container volumes11.5 / 18 / 27 / 44 litres
Max agent content8 / 12 / 20 / 30 litres
Operating temperature range5°C to 65°C
Operating pressure range18.9 bar (min) - 23.7 bar (max)
Agent propellantNitrogen (N2)
Valve constructionStainless steel / brass
Heat sensing tubeModified polyamide, OD 6mm / ID 4mm
CertificationLPCB certified, LPS 1223

Specify it for your next project

If you're quoting a commercial kitchen fit-out or refurbishment and want to know more about the Ultra Series, including pricing, sizing guidance, or design support, get in touch with our team. We're here to help you spec the right system and win the job.

  • LPCB certified under LPS 1223 for stronger compliance conversations and sign-off confidence.
  • Automatic wet chemical discharge with strong cooling and re-ignition prevention.
  • Full extraction-zone thinking covering hood, plenum, and duct requirements.
  • Installer-friendly support with sizing guidance and bespoke design assistance.

Kitchen Suppression Enquiry

Send your enquiry through our contact form and we’ll get back to you. The more survey detail you can provide, the more accurately we can scope the system.

Contact details

Site details

Canopy and plenum dimensions

(External skirt length of Canopy left to right)

(External skirt length of Canopy front to back)

(External height of just the canopy enclosure)

(Cooktop surface to External skirt edge of canopy)

(Top to bottom of internal void)

(front to back internal void)

(underside of canopy to top of filters)

(internal width x depth of each duct connection at the plenum.)

Kitchen suppression canopy and plenum diagram

Appliances and oil load

Include all cooking appliances located directly under the canopy. (e.g. fryers, ranges, grills, Bratt pans, Salamanders). Dimensions to be appliance body only, excluding shelves unless fixed.

System monitoring and integration

Normally Open / Normally Closed - if unknown, select NO.

If NO, additional components will be required within the fire suppression system design.

Cylinder and manual actuator layout

Photos and supporting files

Attach PDFs or images up to 2 MB each. Keep total attachments under 7 MB.

Use this for marked-up drawings, detail shots or extra references. The same upload limits apply.

Your enquiry and supporting files will be captured for our team to review.

Ceasefire Ultra Lite | Commercial Kitchen Fire Suppression System | LPCB LPS 1223

This item is not available to purchase online.

This item is not available to purchase online. Please contact our sales team for more information.

Contact Us

SKU: Ceasefire-Ultra Lite-Commercial-Kitchen-Fire-Suppression-System Category: Brand:
Trade
Account
Enquiry?