Fireray Hub Reflective Beam Detector
£665.00 (inc VAT: £798.00)
Summary
The Fireray Hub Reflective system is a modular beam detection system engineered to meet the demands of challenging fire detection applications. This advanced system combines FFE’s proven reflective motorised beam technology with innovative features including Auto-Alignment™, Building Movement Tracking™ and Light Cancellation Technology™.
Designed for versatility and reliability, the Fireray Hub Reflective enables excellent accessibility and user-configurable settings, ensuring long-term ease of maintenance and ownership. The system controller can support up to three Fireray Reflective Detectors on a single cable run, making it an ideal solution for large public areas, glass atria in hotels and retail complexes, and very large spaces such as warehouses and aviation hangars.
With worldwide approvals including EN54-12 and UL268 7th Edition certification, the Fireray Hub Reflective system delivers dependable performance whilst minimising downtime and maintenance requirements across a wide range of demanding environments.
Features
- Auto-Alignment™ motorised beam technology for automated setup
- Building Movement Tracking™ compensates for natural building shifts
- Light Cancellation Technology™ prevents sunlight nuisance alarms
- Contamination compensation for gradual build-up on optical surfaces
- Dynamic beam phasing allows detectors facing each other
- Individual alarm and fault relays for each detector
- Remote detector fire test from system controller
- Event log with time and date stamps for diagnostics
- Laser-assisted alignment with visible 650nm laser
- 850nm near infrared optical wavelength for smoke detection
- Parallel or network wiring configurations available
- EN54-12 and UL268 7th Edition certified
- IP65 rated controller and IP55 rated detector
- Wide operating temperature range -10°C to +55°C
- UV stable housing in white or grey finishes
FAQ
What detection ranges are available with the Fireray Hub Reflective system?
The system offers flexible detection ranges depending on reflector configuration. With a single reflector, the range is 8 to 50 metres (26 to 164 ft). Using four reflectors extends the range to 50 to 120 metres (164 to 394 ft), making it suitable for very large spaces such as warehouses and aviation hangars.
How does the system prevent nuisance alarms from sunlight?
The Fireray Hub Reflective features Light Cancellation Technology™ that actively compensates for high levels of sunlight and artificial lighting. This technology prevents nuisance alarms in challenging environments such as glass atria in hotels and retail complexes where natural light can be problematic.
How many detectors can be connected to one system controller?
Each Fireray Hub system controller can support up to three Fireray Reflective Detectors. These can be connected using either parallel mode (individually connected) or network mode (connected on a single channel), with a maximum cable length of 100 metres to the furthest detector.
What maintenance advantages does the system offer?
The system enables remote monitoring and testing of detectors without shutting down the protected area, minimising downtime. The Auto-Alignment™ technology reduces manual intervention, whilst contamination compensation handles gradual build-up on optical surfaces. Event logs with time and date stamps provide informed diagnostics for efficient maintenance.
How does the system handle building movement?
Building Movement Tracking™ technology automatically compensates for natural shifts in alignment caused by building movement. This ensures continued reliable operation without requiring frequent manual realignment, particularly important in large structures that may experience thermal expansion or settling.
What certifications and approvals does the system have?
The Fireray Hub Reflective system holds worldwide approvals including EN54-12 and UL268 7th Edition certification. The system is designed to meet local installation standards and can work with both fireproof and non-fireproof cables as required by regional regulations.
Specifications
- Detection Range One Reflector: 8 to 50 m (26 to 164 ft)
- Detection Range Four Reflectors: 50 to 120 m (164 to 394 ft)
- Maximum Detectors Per System Controller: 3 Reflective Fireray Detectors
- Operating Voltage: 14 to 36 Vdc to System Controller
- Operating Current Standard Mode: 12.5 mA (one detector), 15 mA (two detectors), 17.5 mA (three detectors)
- Fast Alignment Mode Current: 33 mA (during alignment or LCD backlight active)
- Operating Temperature: -10 to +55°C (+14 to +131ºF)
- Storage Temperature: -40 to +85°C (-40 to +185ºF)
- Relative Humidity: 0 to 93% non condensing or icing
- IP Rating Controller: IP65
- IP Rating Detector: IP55
- System Controller Dimensions: 170(h) x 274(w) x 73(d) mm (6¾”(h) x 10¾”(w) x 2¾”(d))
- Detector Dimensions: 131(h) x 134(w) x 131(d) mm (5¼”(h) x 5¼”(w) x 5¼”(d))
- System Controller Weight: 1.05 kg (2¼ lb)
- Detector Weight: 0.57 kg (1¼ lb)
- Reflector Weight: 0.06 kg (¼ lb)
- Housing Colours: White RAL9016 UV stable, Grey RAL7001 UV stable
- Housing Flammability Rating: UL94 V0 polycarbonate
- Optical Wavelength Smoke Detection: 850 nm near infrared (invisible)
- Integrated Laser Alignment: 650 nm visible Class 3R <5 mW
- Maximum Angular Alignment Detector: ±4.5° (±70° with adjustment bracket)
- Maximum Angular Misalignment Detector: ±0.5°
- Maximum Angular Misalignment Reflector: ±5°
- Fault Level: Signal dropping by >85% in <2 seconds
- Beam Path Clearance: 0.5 m (1¾ ft) radius from centre line
- Cable Gauge And Type: 2-core, dedicated, 24 to 14 AWG (0.5 to 1.6 mm)
- Maximum Cable Length: 100 m (328 ft) maximum to furthest detector in network mode
- Signal Output: Individual alarm and fault relays (VFCO) max. 1 A @36 Vdc per detector
- Event Log Capacity: 128 events per detector, 600 events per system controller
- Approvals: EN54-12 and UL268 7th Edition certification
Downloads
- Datasheet (Adobe PDF)