Fike TwinflexPro2 2, 4 or 8 Zone Fire Alarm Kit
Summary
A conventional 2-wire fire alarm system is often the natural choice for smaller applications or where budget constraints exist. Fike’s TwinflexPro² 2-wire fire alarm system has long been known for its adaptability and cost-effectiveness within a variety of applications, big or small … making it one of the most flexible products on the market.
The TwinflexPro² fire alarm kits include most of the components required for a full fire alarm system. Each kit contains a 2, 4 or 8 zone TwinflexPro² panel, 7 x Twinflex Multipoint detectors with sounder, 2 x Twinflex manual call points and a head removal tool.
Please note that the Twinflex Pro panels require a pair of batteries for emergency backup which are not included. Wiring for the Twinflex Pro system (fire rated cable, fire clips, etc.) is also not included.
What Is Included In The Twinflex Pro Fire Alarm Kit
- 1 x TwinflexPro² 2, 4 or 8 Zone Pro Fire Alarm Panel
- 7 x Twinflex ASD Multipoint Detectors with Integral Sounder (204 0001)
- 2 x Twinflex Manual Call Points (402 0006)
- 1 x Twinflex ASD Multipoint Detector Head Removal Tool (25 0046 201)
Kindly note the TwinflexPro2 panels included with this kit require 2 x 12V, 3Ah SLA Batteries which are sold separately.
FAQ
What zones are available for the TwinflexPro² panels?
The TwinflexPro² range is available in three configurations: 2 zone (505-0002), 4 zone (505-0004), and 8 zone (505-0008) control panels to suit different installation requirements.
How many devices can be connected per zone?
Each zone can support up to 32 Twinflex devices, dependent on the Device Loading Units (DLUs) not exceeding the stated maximum loading for the circuit.
What cable type is required for installation?
The system requires 2 core 1.5mm² screened fire rated cable with a maximum run of 500 metres per zone. Unlike conventional systems, only one cable is needed per zone for both detection devices and sounders when using Twinflex devices.
Can conventional devices be used with the TwinflexPro² panels?
Yes, the 4 and 8 zone panels can accept conventional devices on zones 5 to 8 with the addition of a conventional zone card, providing flexibility for mixed system installations.
What monitoring capabilities does the panel provide?
The panel monitors each zone for detector head removal, device fault, end of line fault, and open or short circuit faults. It also provides two monitored outputs configurable as sounder circuits and includes fire and fault relay outputs.
How is the panel configured and programmed?
Configuration can be performed using the panel keypad or via PC-driven OSP software connected through the USB interface. The system includes programmable options for alarm confirmation, delay settings, and day/night mode operation.
What power supply requirements does the panel have?
The panel incorporates an integral power supply unit and requires 2 x 12V 3.3Ah batteries for backup power. The mains supply range is 230VAC +10%, -15%, 50/60Hz.
Downloads
- Datasheet (Adobe PDF)
- Twinflex Pro Quick Start Guide (Adobe PDF)
- User Guide (Adobe PDF)
- Engineering & Commissioning Manual (Adobe PDF)


