Infinity ID2 System Configurator
Build a complete Infinity ID2 system by selecting the required components below. Compatible items only. Alternatively, choose only the components you need.
Control Panels
Choose from 2, 4 or 8 zone ID2 panels to suit your system size, with an optional repeater for remote panel display.

- Ability to wire in Radial or Loop modes (selectable on panel)
- Panel shows exact device in fire, "Bedroom 1", "Main Office", etc.
- Verify alarms to reduce false alarms

- Can be programmed to act as fully functional (ability to silence/reset) or passive (shows alarm info only)
- 4 cores required from ID2 panel (2 data + 2 power)
- Can powered from 24V auxiliary PSU in the ID2 panel
Detectors
Infinity ID2 detectors are available with a choice of 5 different smoke and heat detection modes.

- 4 types of detector available
- All available with optional integral sounder
- Remote LED output

- Black plastic moulding to meet aesthetical requirements
- All available with optional integral sounder
- 4 types of detector available
Manual Call Points
ID2 call points for manual alarm activation, available in indoor and outdoor versions.

- Manual call point for the Infinity ID2 system
- Indoor or outdoor (IP67) version available
- Visible warning flag confirms activation
Interfaces
Used to interface your ID2 system with other building systems or equipment.

- Loop powered
- Equipped with short circuit line isolator
- Hand addressed using the 8 way dip switch OR softly addressed using the handheld MKII Programmer

- This is a loop powered device, however loop load calculation must be performed to determine the permissable quantity of ZAZM-MI per loop.
- Hand addressed using the 8 way dip switch OR Softly addressed using our handheld MKII Programmer (part no. MKII-TOOL)
- Equipped with short circuit line isolator

- Allows the Zeta Beam Xtra to be connected to a Zeta MKII addressable loop
- Hard addressed via dip-switches
Sounders & Visual Alarm Devices
ID2 standalone sounders and visual alarm devices for additional audio and visual warning coverage.

- Indoor MKII addressable sounder compatible with Zeta control panels
- 102dB @ 1m sound output
- Available in Red or White

- Combined sounder and VAD in single unit
- 100dB sound output at 1 metre
- Hard or soft addressable capability
Batteries, Power and Isolator Switches
Batteries, power supplies and isolator switches support backup operation and safe maintenance.

- V0 flame retardant claasification
- Stable quality & high reliability
- 5 years design time (at 25 degree C)

- Compliant mains safety isolator keyswitch for fire alarm systems.
- Meets the reuirements of BS 5839 Pt.1 2013.
- Double pole isolation (both live & neutral supply is switched).

- Safely isolate mains supply
- Ensures mains supply is only isolated by authorised persons with key
- Meets BS 5839 Part1 2002
- Available in Red or White
Installer Essentials & Other Compatible Items

- 70% quicker than conventional fire clips
- Suitable for single or double cable runs
- Available in Red, White or Black

- Fire cable clips to suit most cable sizes
- Available in Red, White or Black

An A4 fire log book that allows you to keep critical fire safety information and records in one place

- High quality Stainless Steel cable ties.
- Standard in 316 grade stainless steel.
- Sold in packs of 100.

- High-grade thin wall PVC
- Continuous 100m coils
- Self-extinguishing flammability

- IP68 rated protection for superior environmental sealing
- 6mm-12mm cable diameter range with M20 thread size
- Complete with locknut and ready to use from packaging
Your System
Your system is empty. Add a few items to get started.
Test Product – Infinity Kit Builder
This item is not available to purchase online.
Summary
The EMS SmartCell Wireless Control Panel delivers a complete wireless fire detection solution designed to protect small to medium-sized premises without the complexity and disruption of traditional cabled installations. This compact control panel eliminates the need for extensive cabling work, significantly reducing installation time and site disturbance whilst maintaining full compliance with European fire safety standards.
Supporting up to 64 wireless devices with a maximum of 32 dedicated fire detection devices, the SmartCell system operates across 16 configurable zones using bidirectional communication in the European harmonised 868MHz frequency band. The panel’s 80-character OLED display provides clear system status information, whilst the compact enclosure design enables flexible installation in space-constrained environments. With accommodation for an internal communications card, the system offers future expandability for remote monitoring and SmartCell Services connectivity.
Certified to EN54-2, EN54-4, EN54-13 and EN54-25 standards with full CPR compliance, the SmartCell panel provides installers with a reliable, standards-compliant wireless fire detection solution ideal for retrofit applications, heritage buildings, and installations where traditional cabling would prove disruptive or cost-prohibitive.
Features
The EMS SmartCell Wireless Control Panel delivers a complete wireless fire detection solution designed to protect small to medium-sized premises without the complexity and disruption of traditional cabled installations. This compact control panel eliminates the need for extensive cabling work, significantly reducing installation time and site disturbance whilst maintaining full compliance with European fire safety standards.
Supporting up to 64 wireless devices with a maximum of 32 dedicated fire detection devices, the SmartCell system operates across 16 configurable zones using bidirectional communication in the European harmonised 868MHz frequency band. The panel’s 80-character OLED display provides clear system status information, whilst the compact enclosure design enables flexible installation in space-constrained environments. With accommodation for an internal communications card, the system offers future expandability for remote monitoring and SmartCell Services connectivity.
Certified to EN54-2, EN54-4, EN54-13 and EN54-25 standards with full CPR compliance, the SmartCell panel provides installers with a reliable, standards-compliant wireless fire detection solution ideal for retrofit applications, heritage buildings, and installations where traditional cabling would prove disruptive or cost-prohibitive.
Specifications
The EMS SmartCell Wireless Control Panel delivers a complete wireless fire detection solution designed to protect small to medium-sized premises without the complexity and disruption of traditional cabled installations. This compact control panel eliminates the need for extensive cabling work, significantly reducing installation time and site disturbance whilst maintaining full compliance with European fire safety standards.
Supporting up to 64 wireless devices with a maximum of 32 dedicated fire detection devices, the SmartCell system operates across 16 configurable zones using bidirectional communication in the European harmonised 868MHz frequency band. The panel’s 80-character OLED display provides clear system status information, whilst the compact enclosure design enables flexible installation in space-constrained environments. With accommodation for an internal communications card, the system offers future expandability for remote monitoring and SmartCell Services connectivity.
Certified to EN54-2, EN54-4, EN54-13 and EN54-25 standards with full CPR compliance, the SmartCell panel provides installers with a reliable, standards-compliant wireless fire detection solution ideal for retrofit applications, heritage buildings, and installations where traditional cabling would prove disruptive or cost-prohibitive.
Additional information
| Weight | 1 kg |
|---|