The Vimpex Identileak Sounder (IL-SS) provides essential audible alarm notification for water leak detection systems, delivering loud and clear warnings when leak or fault conditions are detected. Designed for installation in plant rooms, data centres, server rooms and other critical areas requiring strong local audio alerts, the sounder ensures immediate awareness of water escape events to enable rapid response and minimize potential damage to buildings and assets.

Available with or without an integrated blue beacon, the IL-SS sounder offers flexible configuration options to suit different installation requirements and environmental conditions. The distinctive blue beacon provides high-visibility visual identification that clearly differentiates water leak alarms from other building systems such as fire alarms, reducing confusion during emergency response. The clear “Water Leak” branding on the device further enhances identification, ensuring personnel immediately understand the nature of the alarm condition.

The compact, low-profile construction allows discreet integration into building environments while maintaining effective alarm coverage. Compatible with all Identileak control panels including Mini and conventional ranges, the IL-SS sounder connects to the panel’s dedicated sounder circuits and operates at 24V DC. Flush or surface mount installation options provide installation flexibility to suit different architectural requirements. Built to professional commercial and industrial standards with durable construction, the Identileak sounder delivers reliable alarm performance as an essential component of comprehensive water leak protection systems.

Features

  • Low-profile compact design for discreet installation
  • Blue beacon option provides clearly identifiable visual alarm indication
  • Available with or without integrated beacon for flexible configuration
  • Clear “Water Leak” branding on device face for immediate identification
  • Easily identifiable alarm notification differentiates from other building systems
  • Distinctive blue colour separates water leak alarms from fire alarms
  • Flush or surface mount installation options available
  • Compatible with all Identileak control panels (Mini and conventional ranges)
  • Connects to 24V DC sounder circuits on control panel
  • Loud audible alarm for effective notification in noisy environments
  • Suitable for plant rooms, data centres and server room applications
  • Durable construction for commercial and industrial environments
  • Compact form factor allows flexible placement in critical areas
  • Professional-specification alarm device for serious water leak protection
  • Manufactured in the UK by Vimpex

FAQs

What is the difference between the sounder with and without beacon?

The IL-SS sounder is available in two configurations: sounder-only which provides audible alarm notification, and sounder with integrated blue beacon which combines both audible and visual alarm indication. The beacon version is ideal for noisy environments where audible alarms alone may not be sufficient, or in areas where high-visibility visual indication enhances alarm awareness. The blue beacon colour differentiates water leak alarms from red fire alarm beacons.

Why is the beacon blue rather than red?

The blue beacon colour is specifically chosen to differentiate water leak alarms from fire alarm systems which typically use red visual indicators. This colour coding reduces confusion during emergency response, ensuring personnel immediately recognize the alarm as a water leak event rather than a fire evacuation situation, allowing appropriate action to be taken such as water isolation rather than building evacuation.

Can the IL-SS sounder be used outdoors?

The Identileak sounder is designed for indoor installation in dry locations as part of the Identileak system which has an IP30 rating. While the sounder can indicate the status of water detection systems protecting outdoor areas, the sounder unit itself should be mounted indoors in protected locations. For outdoor audible indication requirements, the unit would need to be installed inside a suitable weatherproof enclosure with appropriate IP rating.

How does the sounder connect to the control panel?

The IL-SS sounder connects to the dedicated sounder circuits (S1 or S2) on the Identileak control panel. These circuits operate at 24V DC and are fused at either 300 mA (Mini panels) or 500 mA (conventional panels) per circuit. Multiple sounders can be connected to the same circuit provided the total current draw does not exceed the circuit’s maximum rating. End-of-line resistors must be fitted at the last device on each sounder circuit.

What mounting options are available?

The Identileak sounder is available in both flush-mounted and surface-mounted versions. Flush mounting provides a low-profile installation that sits flush with the wall surface for a neat, integrated appearance ideal for finished areas. Surface mounting allows quicker installation directly onto wall surfaces without cutting into the wall structure, making it suitable for retrofit applications, plant rooms, or areas where flush mounting is impractical.

How loud is the sounder output?

While specific dB ratings are not provided in the standard documentation, the IL-SS is designed to provide loud and clear audible warnings suitable for commercial and industrial environments including noisy plant rooms and data centres. The sounder output is engineered to ensure alarms are heard above typical ambient noise levels in these critical applications, prompting immediate attention to water leak events.

Can I use the sounder with both Mini and conventional Identileak panels?

Yes, the IL-SS sounder is fully compatible with all Identileak control panels including the Mini range (IL-MINI-2) and conventional range (IL-CONV-2, IL-CONV-4, IL-CONV-8). All panels feature dedicated 24V DC sounder circuits to which the IL-SS connects. The sounder draws power from these circuits, so no separate power supply is required, ensuring consistent operation across the entire Identileak product family.

How many sounders can I connect to one panel?

The number of sounders that can be connected depends on the panel’s sounder circuit capacity and the current draw of each sounder. Identileak Mini panels provide 1 sounder circuit rated at 300 mA maximum, while conventional panels provide 2 sounder circuits each rated at 500 mA maximum (1A combined). Multiple sounders can be wired in parallel on each circuit provided the total current consumption does not exceed these limits. Consult the sounder’s current draw specifications to calculate the maximum number per circuit.

Does the sounder require separate batteries?

No, the IL-SS sounder does not require separate batteries. It receives power from the Identileak control panel’s sounder circuits, which are in turn powered by the panel’s mains supply with battery backup. This means the sounder continues to operate during mains power failures when the panel switches to battery backup operation, ensuring continuous alarm capability even during extended power outages.

Where should the sounder be installed?

Sounders should be installed in locations where audible alarms will be heard by personnel who can respond to water leak events. Typical installation locations include corridors outside plant rooms, equipment rooms, data centres, server rooms, or building management areas. Consider ambient noise levels when selecting sounder locations – in very noisy environments, multiple sounders or the beacon version may be necessary to ensure alarms are noticed. Sounders should be positioned to complement rather than replace visual indicators and control panel displays.

Specifications

  • Product Code: IL-SS (sounder only), IL-SB (sounder with beacon)
  • Type: Audible alarm sounder for water leak detection systems
  • Beacon Option: Available with or without integrated blue beacon
  • Beacon Colour: Blue (water leak identification)
  • Profile: Low-profile compact design
  • Branding: Clear “Water Leak” text on device face
  • Mounting Options: Flush mount or surface mount
  • Operating Voltage: 24V DC (powered from control panel sounder circuits)
  • Connection: Connects to S1 or S2 sounder circuits on Identileak panels
  • Circuit Rating (Mini Panels): 300 mA maximum per circuit
  • Circuit Rating (Conventional Panels): 500 mA maximum per circuit (1A combined)
  • Compatibility: All Identileak control panels (Mini and conventional range)
  • Application: Indoor use in plant rooms, data centres, server rooms and critical areas
  • Construction: Durable commercial and industrial specification
  • Purpose: Audible and visual alarm notification for water leak events
  • Differentiation: Blue beacon and “Water Leak” branding distinguishes from other building alarms