Shopping Basket

0 Items

Subtotal £0.00

Conventional Panels

Filter Products

[wcpf_filter_notes filter-id="65037"]

[wcpf_filters id="65037"]

  • Advanced QuickZone XL Conventional or Sav-Wire Panel

    Advanced QuickZone XL Conventional or Sav-Wire Panel

    • Up to 12 zone conventional or twin wire control panel with integral power supply
    • Fully approved to EN54-2 & 4 European standards for fire detection systems
    • Integral 3 amp switch mode PSU with space for up to 2 x 7.0Ah standby batteries
  • Kidde NC Series 2-8 Zone Conventional Fire Panel

    Kidde NC Series 2-8 Zone Conventional Fire Panel

    • Supports up to 1280 devices
    • Intuitive user interface with no language kit required
    • Networkable up to 64 zones
    SKU: NC-PF
  • Esento 12 Zone Repeater Panel

    Esento 12 Zone Repeater Panel

    • 12 zone fully functional or passive operation
    • Intuitive controls with silence, resound, and reset functions
    • Programmable inputs and outputs for enhanced adaptability

    Low Stock

    £296.97 (inc VAT: £356.36)
    SKU: XLEN-R-12
  • C-Tec CFP 2

    C-Tec CFP 2, 4 or 8 Zone Conventional Fire Panel

    • 2, 4 or 8 zone circuits
    • Economy version available
    • Four conventional sounder circuits
    SKU: 7c94faea1764
  • Infinity 1-8 Zone Fire Alarm Panel

    Infinity8 Conventional Fire Alarm Panel

    • Optional 24V aux supply (4-8 zone versions only)
    • Optional non-latching zone
    • Fault relay can be configured as 2nd fire relay
    SKU: af849a707fd8
  • Kentec Sigma CP Conventional 2

    Kentec Sigma CP Conventional 2, 4 or 8 Zone Panel

    • Fully certified to BS EN54-2 and BS EN54-4
    • 2, 4 or 8 version zones
    • Surface and Flush Mounting Options
    SKU: 037c6c8f35f7
  • Morley Horizon 2

    Morley Horizon Conventional Panel

    • Simple, user friendly design
    • 2, 4 or 8 zones
    • Walk test
    SKU: 80ec5d456960
  • Gent Xenex 2

    Gent Xenex Conventional Panel

    • 2, 4 or 8 zone conventional panel from Gent
    • Up to 8 conventional sounder circuits
    • One-man test and commissioning features
    SKU: a710f4a7e074
  • Excel-EN 2-12 Zone Conventional or Twin-Wire Panel

    Haes Esento Excel Sav-Wire or Conventional Panel

    • 2-12 zones
    • Individually selectable Twin Wire zones
    • Network up to 8 control panels
    SKU: cd40d3b13064
  • C-Tec CFP 8 Zone Conventional Repeater Panel

    C-Tec CFP 8 Zone Conventional Repeater Panel

    • Repeats functions of mater CFP panel (Standard Conventional or AlarmSense).
    • Up to 8 repeaters per CFP master.
    • Includes its own Mains power supply that requires its own standby battery supply.

    In Stock

    £149.80 (inc VAT: £179.76)
    SKU: CFP760
  • Esento Conventional Remote Display Unit

    Esento Conventional Remote Display Unit

    • 4 x 40 character LCD display
    • Full system control
    • Fire & fault outputs

    Low Stock

    £400.11 (inc VAT: £480.13)
    SKU: XL-RDU
  • Esento Evoque - 16-32 Conventional Zones

    Esento Evoque – 16-32 Conventional Zones

    • Activate controls via keyswitch or code entry
    • Soft tactile buttons for controls & programming
    • Compatible with most detectors
    SKU: adbd87cf1d96
  • Gent Xenex 13271-08LB 8 Zone Repeater Panel

    Gent Xenex 13271-08LB 8 Zone Repeater Panel

    • 8 zone repeatre panel compatible with Xenex conventional panel.
    • Repeat alarm information in second location.
    • Maximum of only one, 8 zone repeat panel per system.

    In Stock

    £247.20 (inc VAT: £296.64)
    SKU: 13271-08LB
  • JSB FX2200 2 or 4 Zone Conventional Panel

    JSB FX2200 2 or 4 Zone Conventional Panel

    • 2 or 4 zones panels
    • Flexible, high specification system
    • Simple “one-shot” auto-reset user test facility
    This item is not available to purchase online.

    This product is obsolete and has been replaced by:

    View Product

  • JSB FX2200 Conventional Fire Repeater Panel

    JSB FX2200 Conventional Fire Repeater Panel

    • Flexible, High Specification System
    • Simple Auto-Reset User Test Facility
    • Class Change and Programmable Fire/Fault Relay
    • Third Party Approved

    Low Stock

    £226.40 (inc VAT: £271.68)
    SKU: FXRP2200CF
  • Kentec Sigma CP-R Conventional 2-8 Zone Repeater Panel

    Kentec Sigma CP-R Conventional 2-8 Zone Repeater Panel

    • Two-Wire Serial Connection
    • Up to 7 Panels Per System
    • Full Control Over Main Panel
    • 1.2mm Mild Steel Construction
    SKU: 254932883dc1
  • QuickZone 2 or 4 Zone Conventional or Sav-Wire Panel

    QuickZone 2 or 4 Zone Conventional or Sav-Wire Panel

    • 2 or 4 zones.
    • DIL selectable conventional or twin-wire (savwire) set up.
    • Class change and alert inputs.
    • Fire and fault relays.
    • 2 monitored sounder circuits.
    • 1 Amp switch mode PSU.
    • Space for up to 3.2Ah batteries.
    • False Alarm management.
    • Approved to EN54 2 & 4.
    • 3 year warranty.
    SKU: 77e0217b04cd
  • Ziton ZP1 Conventional Fire Control Panel

    Ziton ZP1 Conventional Fire Control Panel

    • Modern, Elegant Design
    • Easy Removable Parts
    • Default Reigonal Set Up
    • EN54 Compliant
    SKU: 19b8ed0b863a
  • Entry levels fire panels with radial wiring for zones & sounders circuits.
  • All sounders & beacons fitted to separate sounder circuits.
Conventional fire alarm panels are certainly the most simple fire panels, both in terms of installation and function. They also offer the most economical prices when compared with 2 wire or addressable panels however installation costs will differ.


To comply with the British fire alarm standard BS5839 a property must be divided into zones, each zone can be considered as physical area for the purposes of locating a fire. We supply conventional panels that range from a single zone up to 24 zones and even 48 zone panels are available upon request. Certainly in the UK it is rare to see any fire system installation using more than an 8 zone conventional panel. Systems greater than 8 zones would benefit from the wiring advantages of 2 wire or addressable fire alarm panels. All detectors and call points for each zone are connected in a radial circuit that starts at the panel and ends at the last device (i.e. a radial circuit is required for every zone). End of line monitoring is achieved by using either an end of line diode or capacitor, which are supplied with each panel and should be fitted into the last final device of every zone. Conventional panels have separate sounder circuits that power any warning devices (sounders, flashers and/or combined).  All conventional panels will have a minimum of 2 sounder circuits as the BS5839 fire standard dictates that in the event of a fault at least one sounder should remain operational. Ideally all sounders should be evenly distributed across both sounder circuits and throughout the property to give the best coverage in the event of a fault such as a cable break. In reality many installations utilise a single sounder circuit for the majority of sounders and simply fit a single sounder next to the panel on the 2nd circuit. Conventional fire systems benefit from wide spread compatibility between various manufacturers panels and devices. Whilst not true in all cases it typically allows an installer to opt for their preferred panel, detectors, call points and sounders from a variety of sources. If you wish to install such a conventional system it is always wise to check the compatibility beforehand. Whilst the simplicity of conventional panels means the biggest defining factor is the number of zones there are some other considerations to bear in mind including the following; The capacity of each sounder circuit will be limited to its current rating. Some conventional panels boast 4 or more sounder circuits which may be preferable depending upon how many sounders you require and/or wiring configuration. BS5839 fire alarm standard outlines that should a detector be removed from its base all manual call points must still be operational. To guarantee this you may decide to install all call points on dedicated zones or in the case of mixed zones ensure the call points are connected before any detectors. Instances where detectors and call points are completely mixed you must use diode bases which maintains the line integrity. As with any fire alarm system battery backup calculations must be undertaken to verify what size batteries are needed to sustain suitable functionality in the event of mains power failure. The size of batteries will be limited to the physical size of the panels’ enclosure so it is always prudent to check the required batteries do indeed fit. If you need assistance choosing the right conventional fire alarm panel feel free to contact us on 01792 452 700.

Trade
Account
Enquiry?